Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations
Title
Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations
Date
2020
Publisher
MDPI AG
Subject
Chordae tendineae
Chordal strain
Comprehensive model
Computer simulation
Edge-to-edge repair
Fluid-structure interaction
Mitral valve
Chordal strain
Comprehensive model
Computer simulation
Edge-to-edge repair
Fluid-structure interaction
Mitral valve
Language
English
Abstract
Edge-to-edge repair for mitral valve regurgitation is being increasingly performed in high-surgical risk patients using minimally invasive mitral clipping devices. Known procedural complications include chordal rupture and mitral leaflet perforation. Hence, it is important to quantitatively evaluate the effect of edge-to-edge repair on chordal integrity. in this study, we employ a computational mitral valve model to simulate functional mitral regurgitation (FMR) by creating papillary muscle displacement. Edge-to-edge repair is then modeled by simulated coaptation of the mid portion of the mitral leaflets. in the setting of simulated FMR, edge-to-edge repair was shown to sustain low regurgitant orifice area, until a two fold increase in the inter-papillary muscle distance as compared to the normal mitral valve. Strain in the chordae was evaluated near the papillary muscles and the leaflets. Following edge-to-edge repair, strain near the papillary muscles did not significantly change relative to the unrepaired valve, while strain near the leaflets increased significantly relative to the unrepaired valve. These data demonstrate the potential for computational simulations to aid in the pre-procedural evaluation of possible complications such as chordal rupture and leaflet perforation following percutaneous edge-to-edge repair.
Source
Biology, Volume 9, Issue 7, July 2020, page 173
Rights
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Format
PDF
Type
Text
Identifier
Bibliographic Citation
Toma, M., Einstein, D. R., Kohli, K., Caroll, S. L., Bloodworth, C. H., IV, Cochran, R. P., Kunzelman, K. S., & Yoganathan, A. P. (2020). Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations. In Biology (Vol. 9, Issue 7, p. 173). MDPI AG. https://doi.org/10.3390/biology9070173
Files
Collection
Citation
Toma, M., Einstein, D. R., Kohli, K., Caroll, S. L., Bloodworth, C. H., IV, Cochran, R. P., Kunzelman, K. S., & Yoganathan, A. P., Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations. Biology, Volume 9, Issue 7, July 2020, page 173, New York Tech Institutional Repository, accessed September 15, 2024, https://repository.nyitlibrary.org/items/show/3758
Position: 516 (18 views)