Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations

Author(s)

Toma, M., Einstein, D. R., Kohli, K., Caroll, S. L., Bloodworth, C. H., IV, Cochran, R. P., Kunzelman, K. S., & Yoganathan, A. P.

Title

Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations

Date

2020

Publisher

MDPI AG

Subject

Chordae tendineae
Chordal strain
Comprehensive model
Computer simulation
Edge-to-edge repair
Fluid-structure interaction
Mitral valve

Language

English

Abstract

Edge-to-edge repair for mitral valve regurgitation is being increasingly performed in high-surgical risk patients using minimally invasive mitral clipping devices. Known procedural complications include chordal rupture and mitral leaflet perforation. Hence, it is important to quantitatively evaluate the effect of edge-to-edge repair on chordal integrity. in this study, we employ a computational mitral valve model to simulate functional mitral regurgitation (FMR) by creating papillary muscle displacement. Edge-to-edge repair is then modeled by simulated coaptation of the mid portion of the mitral leaflets. in the setting of simulated FMR, edge-to-edge repair was shown to sustain low regurgitant orifice area, until a two fold increase in the inter-papillary muscle distance as compared to the normal mitral valve. Strain in the chordae was evaluated near the papillary muscles and the leaflets. Following edge-to-edge repair, strain near the papillary muscles did not significantly change relative to the unrepaired valve, while strain near the leaflets increased significantly relative to the unrepaired valve. These data demonstrate the potential for computational simulations to aid in the pre-procedural evaluation of possible complications such as chordal rupture and leaflet perforation following percutaneous edge-to-edge repair.

Source

Biology, Volume 9, Issue 7, July 2020, page 173

Rights

© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).

Format

PDF

Type

Text

Bibliographic Citation

Toma, M., Einstein, D. R., Kohli, K., Caroll, S. L., Bloodworth, C. H., IV, Cochran, R. P., Kunzelman, K. S., & Yoganathan, A. P. (2020). Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations. In Biology (Vol. 9, Issue 7, p. 173). MDPI AG. https://doi.org/10.3390/biology9070173

Files

biology-09-00173.pdf

Citation

Toma, M., Einstein, D. R., Kohli, K., Caroll, S. L., Bloodworth, C. H., IV, Cochran, R. P., Kunzelman, K. S., & Yoganathan, A. P., Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations. Biology, Volume 9, Issue 7, July 2020, page 173, New York Tech Institutional Repository, accessed April 28, 2024, https://repository.nyitlibrary.org/items/show/3758

Position: 605 (6 views)